Ram ProMaster City HVAC Mystery: No Blower Speed 1 & AC Issues Solved
South Main Auto LLCAugust 28, 202532 min115,136 views
20 connections·32 entities in this video→Diagnosing the HVAC Enigma
- 💡 The Ram ProMaster City presented with a peculiar HVAC issue: no blower on speed 1, yet all other speeds (2, 3, 4) functioned.
- ⚠️ A strange symptom was observed: the A/C light would turn off on speeds 2, 3, and 4, only to turn on when set to speed 1 (where the blower failed).
- 🔍 Initial assumption of a simple A/C leak was quickly dismissed due to the unique blower and A/C light behavior.
Scan Tool Insights and Initial Tests
- 💻 A scan tool was employed to check for relevant HVAC codes or inhibit reasons, but none were immediately apparent.
- 📊 Data stream analysis revealed that the HVAC controller seemed to misinterpret the fan speed knob position, registering speeds 2, 3, and 4 as zero.
- ⚡ Despite the confusing readings, the A/C system itself was functional, as demonstrated by the compressor engaging and providing cold air when the system was manually activated via the scan tool.
The Blower Resistor Hypothesis
- ⚙️ The primary suspect became the blower motor resistor, as it directly controls fan speeds and is a common failure point for low-speed issues.
- ⚠️ The video highlights the difficulty in accessing and removing the blower resistor, requiring specialized tools and techniques due to its design.
- 🛠️ After a challenging removal process, the old resistor was replaced with a new Mopar part.
Resolution and Lingering Questions
- ✅ Upon installation of the new blower resistor, all fan speeds (1-4) were restored, and crucially, the A/C system now functions correctly across all speeds.
- 🤔 The exact electronic interaction between the blower resistor and the HVAC controller remains a mystery, as the scan tool data still showed unusual readings for the knob position, yet the problem was resolved.
- 💡 The takeaway is that a faulty blower resistor, even without setting obvious codes, can cause complex HVAC system malfunctions, including A/C operation issues.
Knowledge graph32 entities · 20 connections
How they connect
An interactive map of every person, idea, and reference from this conversation. Hover to trace connections, click to explore.
Hover · drag to explore
32 entities
Chapters12 moments
Key Moments
Transcript116 segments
Full Transcript
Topics10 themes
What’s Discussed
Ram ProMaster CityHVAC SystemBlower Motor ResistorA/C IssuesNo Blower Speed 1Scan Tool DiagnosisHVAC ControllerAutomotive RepairDiagnostic Trouble CodesElectrical System
Smart Objects32 · 20 links
Products· 13
Concepts· 14
Companies· 4
Location· 1